核心参数
组成要素: 固体激光器产品及设备
其它参数
Based on the novel OPCPA technology
Patented front-end design
Up to 100 Hz repetition rate
Up to 1 J pulse energy
Down to 10 fs pulse duration
Based on the novel OPCPA (Optical Parametric Chirped Pulse Amplification) technology
Patented front-end design (patents no. EP2827461 and EP2924500)
Up to 1 J pulse energy at 5 Hz repetition rate
From Single Shot to 100 Hz pulse repetition rate
Down to 10 fs pulse duration
Up to 50 mJ pulse energy at 100 Hz repetition rate
Excellent pulse energy stability: ≤ 1 % RMS
Excellent long-term average power stability: ≤ 1.5 % RMS over 8-hour period
Perfectly synchronized fs and ps output option available
Hands free wavelength tuning
High contrast pulses without any additional improvement equipment
Broadband CARS and SFG
Femtosecond pump-probe spectroscopy
Nonlinear spectroscopy
High harmonic generation
Wake field particle acceleration
X-ray generation
High Energy UltraFlux laser series delivers up to 30 TW peak power operating up to 10 Hz. Originally built for ELI‑ALPS (Extreme Light Infrastructure – Attosecond Light Pulse Source) in Hungary, this series is now available for a wide variety of applications.
The master oscillator is a patented (no. EP2827461 and EP2924500) all-in-fiber Yb doped picosecond laser seed source with two fiber outputs. One seeds the OPCPA Front-End and another seeds the Picosecond Pump Laser. Both outputs originate from the same fiber so they are optically synchronized.
This approach eliminates the need for a complex temporal synchronization system typically present in other OPCPA systems.
The Nd:YAG Picosecond Pump Laser system (PPL) is comprised of several sub-systems: diode pumped Regenerative Amplifier, diode pumped Preamplifier, flash lamp pumped Amplifiers, and Second Harmonic Generators which convert fundamental 1064 nm wavelength to 532 nm. PPL outputs multiple beams at 532 nm. One beam is directed to NOPCPA Front-End subsystem and others are directed to NOCPA amplification stages.
The Front-End NOPCPA (Non-collinear Optical Parametric Chirped Pulse Amplifier) consists of several sub-systems: Picosecond Optical Parametric Amplifier (ps-OPA) amplifying oscillator output pulses, Grating Compressor compressing ps-OPA output pulses, White Light Generator (WLG) broadening the spectrum of ps-OPA output pulses and Femtosecond Non-collinear Optical Parametric Amplifier (fs‑NOPA) amplifying WLG output pulses.
The Stretcher sub-system is a Grism (diffraction gratings combined together with prisms) or Offner type pulse stretcher, which stretches output pulse from NOPCPA Front-End and Dazzler (optional Acousto-Optic Programmable Dispersive Filter) for high order phase compensation.
Multiple stages of NOPCPA (Non-collinear Optical Parametric Chirped Pulse Amplifiers) are used to amplify the stretched pulse from the Stretcher up to 1 J.
Finally, amplified pulses are compressed back down to fs duration in the Pulse Compressor. Bulk glass compressor (combined together with chirped mirror) or traditional diffraction grating compressor can be used depending on pulse duration required and output energy level.
The built-in Output Diagnostics stage ensures reliable, turn-key operation by monitoring critical parameters such as energy, duration, and beam profile.
Due to continuous improvement, all specifications are subject to change without notice. The parameters marked ‘typical’ are indications of typical performance and will vary with each unit we manufacture. Presented parameters can be customized to meet customer‘s requirements.
Maximum pulse energy specified at 840 nm, SH output at 420 nm, TH output at 280 nm and FH output at 210 nm.
Harmonic outputs are optional. Specifications valid with respective harmonic module purchased. Outputs are not simultaneous. Maximum harmonic energy depends on OPCPA signal beam profile and pulse duration.
Maximum pump energy for harmonics is limited to 10 mJ @ 840 nm.
Standard pulse duration changes though the wavelength range – shortest pulse duration is achieved ~840 nm spectral range.
Separate ‘F10’ option can be ordered to reduce pulse duration to ≤ 10 fs. Wavelength tunability not available with ‘F10’ option.
Under stable environmental conditions, normalized to average pulse energy (RMS, averaged from 60 s).
Measured over 8 hours period after 30 min warm-up when ambient temperature variation is less than ±2 °C.
Super-Gaussian spatial mode of 6-11th order in near field.
Beam diameter is measured at signal output at 1/e2 level for Gaussian beams and FWHM level for Super-Gaussian beams.
Beam pointing stability is evaluated as movement of the beam centroid in the focal plane of a focusing element (RMS, averaged from 60 s).
Pulse contrast is only limited by amplified parametric fluorescence (APFC) in the temporal range of ~90 ps which covers OPCPA pump pulse duration. APFC contrast depends on OPCPA saturation level. Our OPCPA systems are ASE-free and pulse contrast value in nanosecond range is limited only by measurement device capabilities (third-order autocorrelator). There are no pre-pulses generated in the system and post-pulses are eliminated by using wedged transmission optics.
Optical pulse jitter with respect to electrical outputs:
– Trig out > 3.5 V @ 50 Ω
– Pre-Trig out > 1 V @ 50 Ω
– PLL option > 1 V @ 50 Ω
System sizes are preliminary and depend on customer lab layout and additional options purchased.
Longer umbilical with up to 10 m for flash lamp pumped and up to 5 m for diode pumped systems available upon request.
The laser and auxiliary units must be settled in such a place void of dust and aerosols. It is advisable to operate the laser in air conditioned room, provided that the laser is placed at a distance from air conditioning outlets. The laser should be positioned on a solid worktable. Access from one side should be ensured.
Voltage fluctuations allowed are +10 % / -15 % from nominal value.
Required current rating can be calculated by dividing power rating by mains voltage. Power rating is given in apparent power (kVA) for systems with flash lamp power supplies and in real power (kW) for systems without flash lamp power supplies where reactive power is neglectable.
Note: Laser must be connected to the mains electricity all the time. If there will be no mains electricity for longer that 1 hour then laser (system) needs warm up for a few hours before switching on.
Full height with wheels.
Related applications: High Intensity Sources OPCPA Systems
Ekspla激光产品UltraFlux HE的工作原理介绍
激光产品UltraFlux HE的使用方法?
EksplaUltraFlux HE多少钱一台?
激光产品UltraFlux HE可以检测什么?
激光产品UltraFlux HE使用的注意事项?
EksplaUltraFlux HE的说明书有吗?
Ekspla激光产品UltraFlux HE的操作规程有吗?
Ekspla激光产品UltraFlux HE报价含票含运吗?
EksplaUltraFlux HE有现货吗?
更多
企业名称
北京欧兰科技发展有限公司
企业信息已认证
企业类型
信用代码
110108003886158
成立日期
2002-06-14
注册资本
50000
经营范围
技术开发、技术转让、技术咨询、技术服务;计算机技术培训;基础软件服务;应用软件服务;计算机系统服务;数据处理;计算机维修;销售计算机、软件及辅助设备、电子产品、机械设备、通讯设备、五金、交电、化工产品(不含危险化学品及一类易制毒化学品)、文化用品、体育用品、日用品。(企业依法自主选择经营项目,开展经营活动;依法须经批准的项目,经相关部门批准后依批准的内容开展经营活动;不得从事本市产业政策禁止和限制类项目的经营活动。)
北京欧兰科技发展有限公司
公司地址
北京市海淀区上地十街1号辉煌国际中心1号楼1006室
客服电话