沥青中总氮的测量

收藏
检测样品: 建筑工程
检测项目: 有机污染物
浏览次数: 672
发布时间: 2014-08-06
关联设备: 1种 查看全部
获取电话
留言咨询
方案下载

耶拿分析仪器(北京)有限公司

钻石23年

解决方案总数: 527 方案总浏览次数:
方案详情
multi EA 5000 集多个模块于一身,可用来检测固体,液体,粘稠性物体、液化气和气体中的硫,氮,碳,氯含量,由于它的革新技术,multi EA5000 仪器有广泛的应用领域,并且具有很强的适用性和灵活性,是各行业高效的检测工具。 采用德国耶拿公司的multi EA5000元素分析仪,选用水平模式可以准确测定沥青中总氮的含量。

方案详情

analytikjena analytikjena Fields of Application / Industry: Chemistry / Polymer Industry Clinical Chemistry / Medicine/Hygiene / Health Care Cosmetics Electronics Energy Environment/Water/Waste Food / Agriculture Geology / Mining Material Analysis Metallurgy/ Galvanization Pharmacy Refineries/ Petrochemistry Semi-Conductor Technology Others Short Application multi EASeriesDetermination of Nitrogen in Bitumen Introduction Bitumen is a valuable material in the construction industry and in road construction. It is used thereas sealing material and for water protection. Bitumen occurs during the vacuum distillation ofpetroleum in the state of a high-viscosity, almost solid mixture of highly molecular aliphatic andaromatic hydrocarbon compounds. This mixture contains, depending on origin and pretreatment ofthe distilled petroleum, more or less large quantities of organically bonded nitrogen, sulfur andchlorine. These elements are not desired and can initiate corrosion processes, which can lead todefective quality up to destruction of building and pavements. Bitumen can contain up to 5000 ppmnitrogen and 80,000 ppm sulfur. Sample Preparation and Analysis An analyzer of the mult EA Series was used with multi matrix sampler for the tests in thehorizontal operation mode. The bitumen samples to be tested were diluted with a suitable nitrogen-free solvent (e.g. toluene) before the analysis due to its high viscosity. The dilutions so createdwere injected into quartz boats with the aid of the autosampler. Afterwards the boats were fed intothe combustion system by means of the automatic boat drive. Thereby the fed speed is controlledby the flame sensor. The quantitative thermal decomposition was done in a two-phase process.The nitrogen content of the samples was determined with the help of a chemo-luminescencedetector Method settings The method TN_hori_liquid of the standard method library was used for analyzing. Prior to the actual determination of the nitrogen content, the system was calibrated using standardsolutions (pyridine in isooctane). Results Sample cN [ppm] SD [ppm] RSD [%] Bitumen A 276 5 1.8 Bitumen B 316 4 1.3 Bitumen C 603 12 1.9 Bitumen D 2440 38 1.6 Standard 500 ppm 500 16 0.5 Summary The horizontal operation mode of the analyzers of the multi EA Series are outstandingly suited forthe determination of nitrogen contents in Bitumen and related matrices. The multi-matrix samplerallows an optimal adjustment of the sample introduction to the requirements of the matrix to beanalyzed. During parallel operation of a UV fluorescence detector the sulfur content can bedetermined simultaneously. Moreover, the application spectrum can be expanded with additionalaccessory modules to include the parameters chlorine and carbon. Duplication and distribution permitted with reference to source. 2008 Analytik Jena AG Publisher: Analytik Jena AG 07745 Jena Konrad-Zuse-StraBe 1 Phone +49 (0) 3641/77-70Fax +49 (0)3641/77-9279 Publisher:Analytik Jena AG07745 JenaKonrad-Zuse-StraBe 1 Determination of Nitrogen in BitumenReference Number: EA N e|GRO/
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

耶拿分析仪器(北京)有限公司为您提供《沥青中总氮的测量》,该方案主要用于建筑工程中有机污染物 检测,参考标准--,《沥青中总氮的测量》用到的仪器有multi EA® 5000碳、氮、硫、氯 元素分析仪