仪器类型: 普通搁板型
适用范围: 中试型
产地类别: 进口
冻干面积: 0.42平米/0.56平米
真空度: 13ubar(10mT)
捕水能力: 30L
冷凝温度: -85℃
主机尺寸: W×H×D 994mm×2137.6mm×1208.5mm
看了冻干机、冷冻干燥机的用户又看了
SP Hull LyoStar 4.0
SP Hull LyoStar 4.0的设计和制造旨在加快生物制药产品的上市速度,代表了冻干机工程的重大进步。LyoStar 4.0是一款中试规模的冻干机,基于全尺寸生产冷冻干燥机而设计,支持快速扩大规模,提供卓越的层板温度控制,快速层板降温,无与伦比的过程准确性和可靠性。它还包括一套尖端的过程分析技术(PAT)工具,扩展了SP Line of SightTM 技术,克服了在生物制品开发、扩大规模和制造过程中的关键冻干挑战。此外,LyoStar 4.0使用了一种更环保的冷冻气体,减少了冻干过程中的碳排放量。
主要特点
-基于科学的原理进行冻干工艺的开发,提供准确和可靠的数据
-设计和制造基于工业型冷冻干燥机,易于放大
-可集成洁净室或隔离器
-冷阱容积高达30L
-冷阱*温度-85℃
-层板*温度-70℃
-层板可控温度范围-70-+60℃
-配备先进的过程分析(PAT)工具,尽可能大限度地确保过程准确性、可靠性和批次一致性:
*ControLyo®可控成核技术,精确控制冰点,有效改善产品外观,提高批次产品均一性,缩短冻干时间;
*Auto MTM/SMART™冻干技术,主干燥智能优化工具,减少周期开发时间并节省宝贵的API;
*LyoFlux® TDLAS传感器用于蒸汽质量流量测量;
*Tempris®无线传感器实时测量产品温度;
主要优势
减少周期开发时间并节约宝贵的API:使用SMART和AutoMTM工具
易于放大:使用Line of SightTM系列技术、PAT工具和软件
提供额外的产品和工艺信息:如干燥层阻力、热流、传质以及不同的冷冻条件对干燥阻力的影响
尽可能大限度地实现过程控制和可重复性:Line of SightTM PAT工具可实现过程准确性、可靠性和批次一致性
应用领域
配方开发及稳定性研究
冻干工艺优化及规模化
对含溶剂产品进行冷冻干燥
实验室研发及/或小型生产冻干
诊断试剂
96孔板
血清瓶/小瓶
保修期: 1年
是否可延长保修期: 是
现场技术咨询: 无
免费培训: 安装现场提供免费操作培训
免费仪器保养: 无
保内维修承诺: 配件非人为损坏免费更换(耗材除外)
报修承诺: 4小时电话响应,48小时现场服务
美国Virtis Freezemobile 歧管式冻干机
型号:Freezemobile 面议SP台式冻干机Virtis AdVantage Pro
型号:AdVantage Pro 面议美国SP Virtis Ultra 小批量生产型冻干机
型号:Ultra & VirTual 面议Lauda LOOP 恒温循环器
型号:Lauda LOOP 面议Vaccination prevents millions of deaths from infectious diseases per year; however, there are still millions of people who die from these diseases due to weak thermostability demanding cold chains, long-term stability issues and distribution challenges. All these limitations can be overcome by creating a dry product through lyophilization. With the urgency to develop a coronavirus vaccine, it is a crucial time to discuss the process of freeze-drying vaccines.
稳定冻干蛋白配方的合理设计方面的实用建议 Rational Design of Stable Lyophilized Protein Formulations
The objective of this investigation was to evaluate two methods for measuring the maximum sublimation rate that a freeze-dryer will support—the minimum controllable pressure method and the choke point method. Both methods gave equivalent results, but the minimum controllable pressure method is preferred, since it is easier, faster, and less subjective. The ratio of chamber pressure to condenser pressure corresponding to the onset of chokedflflow was considerably higher in this investigation (up to about 20:1) than in previously published reports. This ratio was not affected by the location of the pressure gauge on the condenser; that is, on the foreline of the vacuum pumpversuson the body of the condenser itself. The total water loss due to sublimation as measured by tunable diode laser absorption spectroscopy was consistently within 5% of gravimetrically determined weight loss, regardless of whether the measurement took place during chokedversusnon-choked process conditions.
SP Scientific冷冻干燥机LyoStar 4.0的工作原理介绍
冷冻干燥机LyoStar 4.0的使用方法?
SP ScientificLyoStar 4.0多少钱一台?
冷冻干燥机LyoStar 4.0可以检测什么?
冷冻干燥机LyoStar 4.0使用的注意事项?
SP ScientificLyoStar 4.0的说明书有吗?
SP Scientific冷冻干燥机LyoStar 4.0的操作规程有吗?
SP Scientific冷冻干燥机LyoStar 4.0报价含票含运吗?
SP ScientificLyoStar 4.0有现货吗?
Labconco FreeZone® 冷冻干燥机
EYELA冷冻干燥机FDL-2000
EYELA冷冻干燥机FDU-2110(改款升级为FDL-2000型)
冻干机、冷冻干燥机 YTLG-10A
L6-65/L6-86(plus)实验室基础型冻干机 开谱仪器 Capable 真空冷冻干燥机
台式冷冻干燥机FD-1C-50液晶挂瓶式
上海川纳实验仪器有限公司
中试型冻干机
上海诺乔科学仪器有限公司
德国hallan海朗中试冻干机EX2/5
上海茂默科学仪器有限公司
DGJ-30E(同仓)真空冷冻干燥机,原位冻干机
上海博登生物科技有限公司
最多添加5台
仪器质量可靠 反应迅速 应用场景多 节约耗材 售后完善 响应迅速