核心参数

Monitor

Static Control

Antistatic, Mats / Checker / Monitor

Multimount Continuous

Surface Resistance Checker

Easily determine if a surface is dissipative,  


Continuously monitors single operator and ESD workstation—

eliminating the need for periodic testing

■ Meet ISO 9000 and ANSI/

ESD S20.20 test logging  

requirements

■ Audible and visual alarms

notify operator of  

out-of-limit conditions

■ Easily install on most

equipment or workbench  

surfaces

Use this continuous monitor to  

ensure that critical ESD generators  

conductive, or insulative

 Ensure compliance to

ANSI/ESD S20.20-2007  

per ESD TR53

 Use optional electrodes

for resistance  

measurements of  

larger surfaces

This portable meter is perfect  

for quick checks of surface  

resistance for ESD control  

applications in electronics  

manufacturing or handling  

environments. Simply press and  


in sensitive areas are effectively  

grounded. Unit features green (grounded)  

20028-08

hold the test button until the bright  

LEDs display the reading level.  

Unit features an automatic test  


and red (not grounded) LEDs notifying operator of continuous

personal and mat grounding status.

The 4-mm parking snap allows time for the operator to disconnect

the coil cord from the wrist band and park it on this snap. While

parked, the coil cord disables the alarm, allowing the operator to

leave the workstation. Upon returning and removing the coil cord

from the parking snap, the operator has six seconds to hook up to

the wrist band before the alarm sounds.

What’s included: two 6-ft (1.8-m) mat monitor cords, two push-

and-clinch snaps, mounting hardware and brackets, one set of

voltage selector allowing the test  

voltage to switch from 10 V to  

100 V if the measured resistance  

exceeds 1 x 10E5 ohms. Two banana  

jacks and an electrode toggle switch  

allow for the connection of two  

optional external 5-lb electrodes that  

measure surface resistance point to  

point, or resistance to equipment ground.

What’s included: one 9 V battery and


20028-01


hook-and-loop fasteners, and

NIST-traceable calibration report supplied by the manufacturer.

Specifications

Range: 500 KΩ to 10 MΩ Dimensions (L x W x H):

NIST-traceable calibration report supplied by the manufacturer.

Specifications

Range: 10E3 to 10E12 ohms Power: one 9 V battery

Accuracy: ±1?2 decade  Dimensions (L x W x H): 51?4" x 3" x 1"


Alarm response time: <50 ms

Catalog number Description

33?4" x 2" x 1" (9 .5 x 5 x 2 .5 cm)

Power (50/60 Hz)


Price

Display: 10 colored LEDs

Catalog number


Description

(13 .3 x 7 .6 x 2 .5 cm)


Price


SN-20028-08

Continuous static

control monitor

220 VAC

SN-20028-01

Surface resistance checker


ESD Mats

Eliminate static from your work area

SN-20028-03 Test leads, one pair .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

SN-20028-05 External electrodes, 5 lb, one pair  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

 

Specifications

Compliance: ANSI/ESD S20 .20


Catalog

Statfree

Dimensions

RTG


number

  Benchtop mats

material type (L x W x thickness)

(Ω) Package Price


  SN-26809-60? T2, blue

  SN-26809-61? T2, gray

48" x 24" x 1?16"

(122 x 61 x 0 .2 cm)

106 to 108

dissipative

Mat kit


SN-26809-62 T2, blue 480" x 24" x 1?16"

side/

Roll


26809-60

26809-61

26809-74

SN-26809-64 T2, gray

SN-26809-63 T2, blue 480" x 36" x 1?16"

SN-26809-65 T2, gray

<104

conductive

side

Roll


Desco mats are available in a variety of materials for your static  

control applications and meet ANSI/ESD S20.20 requirements.

Statfree® Type T2 Benchtop Mats have superior heat-, chemical-,

  Floor mats

SN-26809-73?

  SN-26809-74??

CV

i

72" x 48" x 1?8" 103 to 105 Mat kit

36" x 24" x 1?2" 103 to 105 Mat kit


and wear-resistance. All feature two layers of 100% nitrile  

butadiene industrial-grade rubber; the top layer is dissipative and

the bottom layer is conductive. Available in blue or gray, in kit  

or roll.

Statfree® Type CV Floor Mat Kit has excellent chemical-resistance,

is humidity independent, and is made of conductive vinyl.

Statfree® Type i Floor Mat Kit interlocks to provide anti-fatigue

properties over large areas. Mat features conductive rubber  

construction and an ergonomic dome/support cell structure design.

???Includes ground kit 26809-66        ?Includes ground kit 26809-76  

Includes snap kit 26809-68

SN-26809-66 Wrist strap/bench mat common ground kit.

Includes common point 15-ft (4 .6-m) ground cord, resistor with  

10-mm snap stud, and universal snap kit 26809-68  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

SN-26809-68 Universal snap kit. Includes one 10-mm male stud,

one 10-mm female socket, and one long and one short screw  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

SN-26809-76 Floor mat ground kit. Includes 15-ft (4 .6-m) ground cord,

resistor with 10-mm snap stud, and snap kit 26809-68  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

Compact Static Charge Meters

Static Control

Antistatic, Meters / Blowers / Test Kit

St


Measure the magnitude and polarity of electrostatic fields produced by charged objects

Analog Meter instantly measures static charges. Achieve higher resolution when

measuring below 3000 volts by setting the range selector to LOW setting; measure up to

30,000 volts in the HIGH range simply by multiplying the reading by ten. The “quick zero”

function re-zeros the meter for repetitive measurements.

Digital Meter with Output measures electrostatic fields by increasing the meter to charged

surface distance. Meter features a 31?2-digit, 0.4"H LCD. HOLD button freezes current

reading. Easily zero the meter with the turn of a knob, there is no need to re-zero between

measurements. The output lets you permanently record your results. Order charge plate

detector separately below to verify proper operation of air ionizers and increase meter

sensitivity by a factor of ten.

What’s included: one 9 V battery. Digital meter 37715-70 also includes a carrying case.


Analog meter

17797-30


Leather case

17797-32


Catalog number Type

SN-17797-30 Analog

Range

0 to 30,000 V

Output

Dimensions (L x W x H)

43?8" x 25?8" x 13?8" (11 .2 x 6 .7 x 3 .5 cm)

Price


SN-37715-70 Digital 0 .00 to ±19 .99 kV at 1" 10 mV/kV 41?4" x 23?8" x 1" (10 .8 x 6 .1 x 2 .5 cm)

SN-17797-32 Leather case for meter 17797-30 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

SN-09376-04 Replacement batteries, 9 V . Pack of 4 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

 

 Ionized Air Blowers

Automatically maintain a balanced ion output

Portable Ionized Air Blower is compact, lightweight, and ideal for

field use. Blower features an emitter cassette that slides out for easy  

cleaning and replacement. The grounded metal case eliminates  

high-voltage fields for greater safety. Airflow output can be adjusted  

for greater worker comfort. Visual and audible alarms and  

“Clean Me” indicator automatically signal when cleaning and  

maintenance are required.

Benchtop Ionized Air Blower emits ions in a true laminar flow

reducing ion recombination and emitter contamination. AC ionizing  

system neutralizes static charges at a greater distance while the fixed  

temperature heater increases worker comfort. Gold-plated emitters  

provide longer service life.

What’s included: NIST-traceable calibration report supplied by the manufacturer

and a 71?2-ft (2.2-m) power cord (on 120 VAC models only).

Catalog number Type Max airflow output Dimensions (W x H x D) Power (50/60 Hz) Price

SN-26809-44 Portable 81?2" x 73?4" x 31?2" 120 VAC 

26809-50 Digital meterwith output

37715-70 SN-26809-46

SN-26809-50 Benchtop

77 cfm

117 cfm

(21 .6 x 19 .7 x 8 .9 cm)

11" x 9" x 7"

240 VAC

120 VAC


SN-26809-52

(27 .9 x 22 .9 x 17 .8 cm)

240 VAC

26809-44 SN-26809-48 Replacement emitter cassettes for portable ionized air blower . One pair  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

 Ionization Test Kit

Provides convenience and portability for testing of air ionizers

Use this ionization test kit to conduct regular auditing of air ionization equipment ensuring

compliance. Test kit includes a static field meter to measure the offset voltage (balance)

and charge decay of air ionizers, along with a charger for placing a ±1000 V charge on

the included conductive plate to meet ANSI/ESD SP3.3 standards. System is easy to use;

place the plate assembly on the static field meter, zero the meter, and then begin taking

measurements. Static meter also features a Hold function allowing you to easily read or

save measurements on the screen for later reference.

What’s included: digital static field meter, slide-on conductive plate, charger, data output

cord, carrying case, two 9 V batteries, and NIST-traceable calibration report supplied by  

the manufacturer.

Specifications


Range 

Low: 0 to ±1 .99 kV / inch

High: 0 to ±19 .99 kV / inch

 

 

Catalog number

SN-20028-09

Accuracy   

Monitor output: > ±5% of reading

±10 mV; Display: > ±5% of

reading ±2 counts

 

Description

Ionization test kit

Stability: ±10 counts

Display: LCD

Power: one 9 V battery

Dimensions (L x W x H): 5" x 23?4" x 1"

(12 .7 x 7 x 2 .5 cm)

Price


美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器

用户评论
暂无评论
问商家

其它常用设备17797-30/17797-32/26809-50/37715-70的工作原理介绍

其它常用设备17797-30/17797-32/26809-50/37715-70的使用方法?

17797-30/17797-32/26809-50/37715-70多少钱一台?

其它常用设备17797-30/17797-32/26809-50/37715-70可以检测什么?

其它常用设备17797-30/17797-32/26809-50/37715-70使用的注意事项?

17797-30/17797-32/26809-50/37715-70的说明书有吗?

其它常用设备17797-30/17797-32/26809-50/37715-70的操作规程有吗?

其它常用设备17797-30/17797-32/26809-50/37715-70报价含票含运吗?

17797-30/17797-32/26809-50/37715-70有现货吗?

美国Desco静电消除器信息由上海拜普实业发展有限公司为您提供,如您想了解更多关于美国Desco静电消除器报价、型号、参数等信息,欢迎来电或留言咨询。
移动端

仪器信息网App

返回顶部
仪器对比

最多添加5台